Adjusting a sporlan txv

SD-289 - Sporlan TEV Installation and Instructions SD-414 - Sporlan FX TEV Installation and Instructions Sporlan Replacement Parts - Bulletin 122 Product Demos & Tutorials; HVACR Tech Tip: Introduction to Thermostatic Expansion Valves (TEVs) How to Adjust Thermostatic Expansion Valve Superheat for HVACR Applications

Adjusting a sporlan txv. For more tips, visit our website, http://www.edgetekhvac.com.

Installation. For peak performance, it is important to select a Sporlan Thermostatic Expansion Valve (TEV) with correct capacity, selective charge, external or internal …

This is the Sporlan BQ TEV kit that I have talked about for a while now, many people have asked me to talk about it and I decided to go one step further and ...Problem. 16RQ. Step-by-step solution. Chapter 5, Problem 16RQ is solved. View this answer. View a sample solution. Step 1 of 2. Step 2 of 2. Back to top. Welcome to Parker Sporlan's Virtual Engineer Sizing and Selection Tool Parker Sporlan's Virtual Engineer is an innovative design tool for climate control and refrigeration applications. Save engineering time with three simple steps: "Why are you adjusting that Thermal Expansion Valve?" To answer this question we first need to look at the main functions of the TXV. The TXV is designed to keep the evaporator as full of saturated refrigerant as possible while at the same time protecting the compressor from slugging or overheating. This is accomplished by maintaining a set ...Adjustable beds are becoming increasingly popular as people look for ways to improve their sleep quality and comfort. With so many options available, it can be difficult to know wh...EFVE1C. $ 299.54 View Contractor Pricing. View Inventory. Expansion valve, standard port, R22 family, external equalizer, 1 ton, 1/4" ODF inlet x 1/2" ODF outlet, C charge (medium temp) Quantity. Add to Cart.Sporlan - 168198 - TXV SBQE BODY 3/8" x 1/2" x 1/4" ODF External Equalizer Angle. Item: SBQEBODY381214ODF. MFG: 168198. loading availability. Loading price. / EA.These features of the TXV valve are explained below. Another name for the TXV valve is the thermal expansion valve. By controlling the flow of the liquid refrigerant with the TXV valve, the evaporator on your air conditioning unit or heat pump will run more efficiently. The TXV valve also serves to protect the mechanical reliability of the unit.

The cap located at the bottom can be removed. This will expose a 1/4" square valve stem (like a king valve stem) Rotating clockwise will increase the spring tenstion and increase the superheat. All adjustments should be 1/4 turns at a time with a few minutes between adjustments. Set the valve for 10-12 degrees superheat.These valves have a removable 100 mesh strainer as a standard feature. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Overall height: 3.76" Element size: 43; Capillary length: 30"Jan 26, 2019 · Sporlan – Turn all the way in clockwise, and then go out 4 ½ turns counterclockwise. Let it set and equalize, and then check after 15 mins. The goal is a 6-12-degree superheat. When adjusting, make minor adjustments, and then let it sit and wait for adjustments to show. —Clayton. #Rack refrigeration #TXV. A thermostatic expansion valve (TXV) (see Figure 1) is a refrigeration and air conditioning throttling device that controls the amount of refrigerant liquid injected into a system's evaporator—based on the evaporator outlet temperature and pressure—called the superheat. Figure 2 shows the different phases and pressures the refrigerant ...Bulletin 10-11 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly: Bulletin 210-40-4 - Sporlan Field Conversion of the Thermostatic Expansion Valves with Replaceable Thermostatic Elements: Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification: SD-289 - Sporlan TEV Installation and InstructionsDesuperheating Thermostatic Expansion Valve - When the desuperheating TEV is used in conjunction with the bypass valve, piping the two valves to get good mixing before reaching the TEV bulb location is vital. This can be accom-plished several ways but the simplest is to tee the liquid-vapor mixture from the TEV and the hot gas from the DBV

In this video I swap out a power head on a TXV without recovering the refrigerant. #airconditioner #hvaclife #hvactechnician #hvacguy #acrepair #hvac #hvacin...This Parker Sporlan webinar training module will discuss Thermostatic Expansion Valves (TEVs) - Supermarket Metering Devices. This is part of our former Supe...#8 — Check the TEV Adjustment: The factory setting of a Sporlan TEV is close to center stem. Count the total number of turns from front seat to back seat, then front seat the adjustment stem 50% of the total turns counted. Turn the adjusting stem clockwise in increments of 1/2 to 1 full turn every 15 minutes until the correct superheat isOct 20, 2013 · The ONLY way to verify operation of a TEV is to check the superheat and adjust it to your need. 10 degrees might be fine for AC purposes, but I need things quite a bit cooler than that for refrigeration sometimes. Reply. 10-21-2013, 06:42 AM #11. Bulletin 210-40-4 - Sporlan Field Conversion of the Thermostatic Expansion Valves with Replaceable Thermostatic Elements Bulletin 210-60 - Sporlan Thermostatic Expansion Valves Identification SD-14 - Sporlan Thermostatic Expansion Valves Installation, Field Service, and Assembly SD-289 - Sporlan TEV Installation and Instructions

Rotg fanfic.

Sporlan's OVE-40CP100 Thermostatic Expansion Valve is ideal for both residential and commercial HVACR applications. With a nominal capacity of 40 tons, it is designed with a 1-1/8 ODF inlet, a 1-3/8 ODF outlet, and is rated for use with R22 or R407C refrigerants. This expansion valve is built for durability, with an equalization type of ...687472490449. Width. 3.75. Country of Origin. USA. Thermostatic Expansion Valves10 Outstanding Features & Benefits of Sporlan Thermostatic Expansion ValvesSelective Thermostatic Charges Designed to provide optimum performance for all applications-air conditioning and heat pump, medium and low temperat.Parker Expansion Valve Quick Reference. Parker Expansion Valve - Quick Reference. Parker Hannifin orporation, roadview, IL USA 800-742-2681 P-109-0712. Orifice R-12 / R-134A R-404A / R-507 R-22 / R-407 R-410A AAA* N/A 1/8 to 1/6 1/6 to 1/3 N/A AA 1/6 to 1/4 1/6 to 1/4 1/3 to 1/2 1/3 to 1/2 A 1/2 to 1 1/2 to 1 3/4 to 1½ 3/4 to 1½ 1 to 2 1 to 2 ...Expansion Valve (TXV) - R-410A, 3-Ton, 3/8 in. Inlet, 3/8 in. Outlet. IMPORTANT: Heating, ventilation, air conditioning or refrigeration parts and accessories should only be installed by qualified technicians. Failure to understand and follow the manufacturer's installation and use instructions may result in fire or explosion, electric shock ...Sporlan 130734 - SVE-5-C 1/2" x 7/8" ODF Thermal Expansion Valve w/ 60" Capillary (5 Ton)- Specifications: REFRIGERANT TYPE: R-22 APPLICATION: Commercial Refrigeration THERMOSTATIC CHARGE: C NOMINAL CAPACITY (TON): 5 INLET CONNECTION: 1/2" ODF OUTLET CONNECTION: 7/8" ODF EQUALIZER METHOD: Externally Equalized CAPILLARY LENGTH (INCH): 60 ...Thermostatic Expansion Valve - Type BBI (OEM Only) The Type BBI valve is a small capacity balanced port valve designed for use on residential and small commercial air conditioning systems up to 15 tons. The BBI can also be used in packaged heat pump units. The R/ER series valves serve as replacements.

Sporlan is one of today's greatest HVAC system and component manufacturers, their products receiving numerous acclaims from HVAC technicians, engineers and domestic users from the entire world. The success of Sporlan in the HVACR industry has been marked by the philosophy of its founding fathers: Harold T. Lange and Hermann F. Spoerher (hence the name Spor from Spoerher and Lan from Lange ...These valves have a removable 100 mesh strainer as a standard feature. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Overall height: 3.76" Element size: 43; Capillary length: 30"expansion valve, the thermostatic expansion valve, and the elec-tric expansion valve. The fixed area restrictor expansion device is simply a precisely formed restriction through which liquid refrigerant flows. Two common examples of this type of device are the capillary tube, or cap tube, and the short tube restrictor, or plug orifice.If a display is too large and is causing some of the objects on the screen to be unseen, adjust the display size using the screen resizing buttons present on the monitor. Another o...Type FX/FXC. TEV INSTALLATION INSTALACION DE VALVULAS DE EXPANSION TERMOSTATICA INSTALLATION DES TEV (THERMOSTATISCHES EXPANSIONSVENTIL) INSTALLATION DES DÉTENDEURS THERMOSTATIQUES INSTALLAZIONE DELLE VALVOLE D’ESPANSIONE TERMOSTATICHE INSTALAÇÃO DAS TEV (VÁLVULAS DE EXPANSÃO TERMOSTÁTICA) SD-414 / 42023. 0.Page 2— BULLETIN 10-10-8. The Sporlan Type R Valve family features balanced port design, an external adjustment assembly and the replaceable element assembly. The Type R with extended copper connec- tions has recently been expanded to include three conventional body styles, the R, ER, and SR plus new fractional capacity versions.DAE15L - Expansion valve, standard port, NH3, external equalizer, 15 tons, 1/2" FPT inlet x 1/2" FPT outlet flanged, L charge (liquid) ... Sporlan type D valve is a gray cast bronze body, externally adjustable valve available with FPT flange connections. The thermostatic element is replaceable and all internal parts are replaceable.This Sporlan Expansion Valve also adopts a brass body and is able to adjust flow capacity . This Sporlan Expansion Valve makes use of the huge and flat stainless steel film and the design of needle valve base, making needle valve match correctly with valve port and keeping good tightness between them. This Sporlan Expansion Valve is known to ...When to Replace Expansion Valve: 3 Telltale Signs. Pressure Control and Expansion Valve: A Complete Guide. TXV vs Expansion Valve: A Comprehensive Comparison. Adjusting Superheat on TXV: In 6 Simple Steps. Sporlan TXV Superheat Adjustment: Your Step-by-Step Guide

These valves have a removable 100 mesh strainer as a standard feature. These valves are designed for small refrigeration systems such as refrigerated cases, coolers, and freezers where space is limited and an external adjustment is desired. Overall height: 3.76" Element size: 43; Capillary length: 30"

Use this bulletin to cross reference a standard Sporlan valve for replacement with a Sporlan Conventional Port (Type Q) valve in four easy steps: 1. Identify the valve to be replaced. The valve's body type, nominal capacity, and thermostatic charge can be determined by inspecting the valve. See the example below for a breakdown of a valve'sTXV Installation Instructions. DO NOT oil threads. Before installing the TXV, install one. O-ring on the Liquid Line Fitting. Install the other O-ring on the Inlet Tube Assembly. See Figure 3. Connect the TXV by hand to ensure proper mating of threads. Tighten until bodies "bottom" or a definite resistance is felt.In this video I go over Sporlan txv selection for refrigeration applications.This category contains Power Elements manufactured by Parker Hannifin for C(E), SC(E), and EC(E) series valves.One more thing to mention, The freezer that I am talking about does have a semi-hermetic and oddly enough before the 502 gas was changed to 404a, the system already had POE in it. The compressor is a Copeland with POE stamped on the data plate. And yes it is a Norlake which is common for Subway.Expansion valve, balanced port, R22 family, external equalizer, 1-1/2 ton, 3/8" MFL inlet x 1/2" MFL outlet, C charge (medium temp), 169378. Quantity. Add to Cart. Nearby Stock. Add to Job List Compare Email a friend. View Catalog Page . Product Details. Vendor Name: Sporlan URI Part Number: RVE1-1/2C Vendor Part Number: 169378 Shipping Weight ...Adjustable foot pedals are a common option found on many GM vehicles such as the Chrysler 300 and Chevrolet Malibu. There are also custom adjustable pedals that can purchased and i...

Mary from hell's kitchen season 11.

Meineke laconia.

The only precaution is to verify this thermostatic expansion valve capacity at the reduced pressure drop across its port. Sometimes you may get lucky and the orifice size will be stamped on the distributor body. ... For a free copy of Sporlan's selection and sizing program, contact your local sales engineer or call 636-239-1111. You must ...6. Select the Sporlan Selective Thermostatic Charge. Select the charge according to the design evaporating tem-perature from the Table on page 3. Refer to Bulletin 10-9 for a complete discussion of the available Sporlan Selective Thermostatic Charges. Selection Example – Refrigerant 22 Application: medium temperature refrigerationAug 31, 2017 · TXV Selector Tool Emerson is pleased to announce the launch of the TXV Selection Tool. This online selection tool allows users to enter their HVACR system characteristics such as refrigerant type, temperatures, pressure drop and capacity, and then selects the best Emerson thermal expansion valves for the application. ported TEVs, like Sporlan BF and O series valves, have a much greater ability to follow load than conventional TEVs, but still not to the extent that EEVs can. The resolution of an Electric Expansion Valve or EEV is governed by the stroke and number of steps in that stroke. Sporlan offers valves in a variety of sizes for a multitude ofSporlan Type F with SAE flare connections or Type EF with ODF solder connections are small brass bar body valves with identical internal construction and replaceable thermostatic elements. The Type F valve has a removable 100 mesh strainer as a standard feature. The Type EF has a 60 x 50 mesh insert strainer.Adjusting a Nelson sprinkler head is a simple process that only takes a few minutes to complete. To adjust your Nelson sprinkler head, you need access to the sprinkler itself and t...So... you’re six weeks into your new life in a new city. So... you’re six weeks into your new life in a new city. Or six months. Or a year. No matter how long it takes, at some poi... ….

Keeping your brakes working properly is an important part of vehicle maintenance. If your vehicle has drum brakes, you need to adjust them periodically to prevent them from draggin... Sporlan Division Products can and do fail without warning for many rea-sons. Design all systems and equipment in a fail­safe mode, so that fail­ ure of these products and related accessories will not endanger persons or property. Pressure Rating: The maximum internal pressure of the Y1037, Y1210 and Y1244 valves is 500 psig (34 bar). Expansion Valve Parts Kit ; Kit Contains: 1 Seat, 1 Pin & Carrier, 2 Push Rods, 1 Seal Cap Gasket, 2 Flange Gaskets, 1 Bottom Gasket, & Form 38-14-692 ... For over 80 years Sporlan has set the industry standard for the development and manufacture of leading edge HVACR components. Brief content visible, double tap to read full content. ...About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...through connections and external adjustment. The thermostatic element is not replaceable on valves manufactured prior to 1994. Current models use a re-placeable No. 43 element. Typical applications: small capacity air conditioning and refrigeration applica-tions where an external adjustment is desired. Not available for R-410A. RThermostatic Expansion Valve - Sporlan - Type SBF. Sporlan Type SBF thermostatic expansion valves are designed for use on Air Conditioning and Refrigeration units. They regulate refrigerant flow by maintaining a nearly constant superheat at the evaporator outlet.Bulletin 100-20 - Sporlan Electric Expansion Valves - SER, SERI, SEHI: Bulletin 100-20-1 - Sporlan Electric Expansion Valves - SER-AA, -A: Bulletin 100-50-5 - Sporlan Kelvin II Series Electric Valve Controllers: Form 100-304 - SER(2)-C 2nd Generation Electionic Expansion Valve: Form 100-419 - Sporlan Electric Valve Poster: Parker--CO2 ...Setting Subcooling on a TXV System. About this HVAC Tip. Troubleshooting, Heat Pump, AC ; In this video, I determine how to use the subcooling charge curve to adjust the charge properly. Related HVAC Tips. OL is Not an Ohm Reading. Maintenance, AC, Troubleshooting, Installation; Leaving a Voicemail for Tech Support. Business, Troubleshooting ...Bryan does an in-depth review of how to adjust a thermostatic expansion valve, also known as a TXV, TEV, or TX Valve. He explains why one would adjust a TXV ...Dec 26, 2019 · When you’re ready to adjust the TXV, remove the stem cap on the bottom to expose the spindle. It’s easy to make the adjustment if you make a mark at the edge of the spindle. That way, you can keep track of how many turns you make. Many manufacturers recommend turning the spindle only a quarter-turn at a time. Adjusting a sporlan txv, HVE11GA - Expansion valve, standard port, R22 family, external equalizer, 11 tons, 5/8" ODF inlet x 7/8" ODF outlet flanged, GA charge (A/C) ... Sporlan type H valve is a brass bar body, externally adjustable valve available with ODF solder flange connections. The thermostatic element is replaceable and the inlet connection has a permanent 16 ..., Welcome to Parker's Sporlan Division. Parker Sporlan is solving HVAC and refrigeration industry challenges by providing innovative solutions which aid technicians in diagnosing and repairing systems quickly and accurately. Sporlan also offers a range of components and systems that increase energy efficiency and reduce emissions, helping to ... , By Victor Ene. Undertaking a Sporlan TXV superheat adjustment doesn’t have to be a daunting task. In this comprehensive guide, we delve into every aspect you need to know …, The Sporlan Type SR balanced port thermostatic expansion valve has a brass bar stock body. The SR valve has standard or extended ODF Solder connections in a variety of common sizes. The valve is equipped with a serviceable inlet strainer, allowing the strainer to be cleaned or replaced without removing the valve from the system., Software Downloads - Sporlan Division. Sporlan Unit Converter. Convert Units of Measurement. Sporlan Unit Converter. Sporlan Unit Converter. Converts Units of Measurements. Sporlan Product Selection Program - Version 5.05., Want to buy a house, but not sure what kind of mortgage to get? Check out this breakdown of a fixed-rate vs. adjustable-rate mortgage. Emma Finnerty Emma Finnerty Mortgages primari..., A thermostatic expansion valve (TXV) is built up around a thermostatic element separated from the valve body by a diaphragm. Its purpose is to regulate the rate at which refrigerant flows into the evaporator. TXVs can contain one of three different types of charge: universal charge. maximum operating pressure (MOP) charge., On an adjustable valve, increasing the spring tension/force results in lower flow and higher superheat, and decreasing the spring tension/force results in more flow and lower superheat. In short, counterclockwise = lower superheat, clockwise = higher superheat., 415K views 7 years ago. Bryan explains why and how to adjust a TXV and what to consider before doing it. A TXV maintains a constant superheat value at the evaporator outlet, and it needs..., Thermal Expansion Valves (TXV) Sporlan Thermal Expansion Valves. Power Elements. KT-43-SC 30" Power Element Kit. Brand: Sporlan. SKU: 183387. Rating: (0) Q&A: (0) ... Sporlan. Free Shipping. On orders over $99. We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to ..., Parker Hannifin Corp. (Sporlan) 30" Capillary Tube, Thermostatic Expansion Valve Element for Refrigerant, Air Conditioner. Most Sporlan thermostatic expansion valves can be completely disassembled in the field allowing access to all internal parts. Sporlan offers a wide array of high quality replacement parts and long lasting replaceable power ..., When to Replace Expansion Valve: 3 Telltale Signs. Pressure Control and Expansion Valve: A Complete Guide. TXV vs Expansion Valve: A Comprehensive Comparison. Adjusting Superheat on TXV: In 6 Simple Steps. Sporlan TXV Superheat Adjustment: Your Step-by-Step Guide, 16. When adjusting a Sporlan TEV for 2° more superheat , how many turns of the adjustment stem are needed and in what direction? b. Clockwise (in) one half turn 17. How is the factory setting of the superheat adjustment determined on a Sporlan expansion valve? a. Find the mid-point of the superheat adjustment stem., The expansion valve will control superheat at the outlet of the evaporator. It should be selected on the following criteria. • Balanced port Thermostatic Valves: 35% - 107%. • Non-balanced port Thermostatic Valves: 45% - 100%. • Electric Stepper Valves: 10% - 80%. • Pulse Width Modulation (Sporlan SPW Valves): 50% - 85%., ERVE-1-C 1/4" x 1/2" ODF Thermal Expansion Valve w/ 60" Capillary (1 Ton) SKU: 169185. Sporlan. Sporlan Thermal Expansion Valves (TXVs) are available in a variety of heat pumps, air conditioning, and refrigeration applications. Here you can find a Thermostatic Expansion Valve for nearly any HVAC job. , I'm not sure that it does. I'm hearing a lot about not adjusting the TXV however I'm hearing a couple of guys that I trust say that if the SH is too high and suction is too low to go ahead and adjust it. Are the airflows correct, probably not, this unit is probably oversized for the duct., Learn how to adjust Thermostatic Expansion Valve # superheat and why you need to do it. Learn the steps needed to properly adjust Parker Sporlan # TEVs to ensure the most desirable operation. # TXV # HVACR # refrigeration # HVAClearning https://prker.co/35Q17tT, , The Sporlan OVE-20CP100 Thermostatic Expansion Valve is ideal for light commercial and all residential HVACR applications. It is designed to regulate the flow of refrigerant, providing steady compressor performance while maintaining uniform ability and pressures. This model has a nominal capacity of 20 tons and features 7/8 ODF inlet x 1-3/8 ..., Print Product Overview. Description. The Sporlan Type SBF balance ported thermostatic expansion valves have a brass bar stock body with flare or sweat connections, adjustable superheat, long lasting replaceable power element and accessible internal parts. Each valve is factory tested to ensure positive leak-free performance., Connect the Electric Expansion Valve (EEV) wires to terminals 5, 6, 7, and 8. ... Sporlan Superheat Control Installation and Operation Manual ... and download Bulletin 100-50-5.1 3. OPERATION For further system tuning, adjust parameter setpoints as described below and in Bulletin 100-50-5.1. 1. Enter the Parameter Menu: Hold down the SELECT ..., The Sporlan Type ER balanced port thermostatic expansion valve has a brass bar stock body. The ER valve has ODF connections in a variety of commons sizes, and has an optional inlet strainer available. There is also an option for a 15% bleed port, if required., 1.TYPE VALVE -Sporlan thermostatic expansion valves are available in three body styles — SAE flare, ODF sol-der, or flange. The first letter or letters stamped on the valve body and shown on the label designates the valve type. Valve types are listed below. 2.REFRIGERANT -Sporlanvalves are available for use with most popular refrigerants., Learn how to identify a Parker Sporlan Thermostatic Expansion Valve (TEV). For more information visit Sporlan.com and view Parker Sporlan Bulletin 10-10.http..., Re: Adjusting Sporlan TXV for SH. Adjusting the superheat setting may only serve to mask your problem and should not be undertaken lightly. You should really …, Evaporator Pressure Regulation. Sporlan Evaporator designed to provide Pressure an economical Regulating valves (EPRs) are means of accurately maintaining varying evaporator evaporator loads. pressure The primary and function temperature of an under EPR is to prevent the evaporator pressure predetermined value temperature is or setting., Expansion Valve (Orifice Tube) Replacement Cost. Service Location. SELECT YOUR VEHICLE. $420.66 - $1,770.96. Price range for all vehicles. ( 47) Most cars nowadays have air conditioner. We love to have the feel of the cool air on those hot summer days, and we don't often think about what's involved in making sure the air conditioning runs ..., I completely disagree, comparing a danfoss tuae valve which has 9 selectable orifice sizes to say a sporlan balanced port valve (SBF series) which has only 5 - leaves a lot of room for mismatching evap load to valve capacity with the sporlan valve. ... The biggest problem is not TXV adjustment it is the lack of understanding of superheat ..., TXV Selector Tool: Emerson is pleased to announce the launch of the TXV Selection Tool. This online selection tool allows users to enter their HVACR system characteristics such as refrigerant type, temperatures, pressure drop and capacity, and then selects the best Emerson thermal expansion valves for the application., equipment manufacturer or Parker Hannifin -- Sporlan Division. • Sporlan is not responsible for any damage which may be caused by misuse or by installation of parts, accessories or controls which are not on the original specification. • Hot or cold parts of the valve which present a danger to the operator must be protected. , TXV superheat adjustment If these issues cannot be corrected by any other way, adjust the valve's superheat. Note: adjusting the superheat should only be done after all other corrective measures have been taken. When adjusting the superheat (as seen in Figure 5), verify the rate of change per turn of the superheat spindle for the specific TXV, Sporlan - 168015 - TXV SQE BODY 3/8" x 1/2" x 1/4"ODF External Equalizer Angle . Parker Sporlan . Sporlan - 168015 - TXV SQE BODY 3/8" x 1/2" x 1/4"ODF External Equalizer Angle ... TXV/TEV - Thermostatic Expansion Valve: Outlet Connection Size: 1/2" ODF: Package Height: 6.25: Package Length: 14.5: Package Weight: 21.56: Package Width: 13: Prop ..., When adjusting both evaporator pressure regulating valves and thermostatic expansion valves, the follow-ing procedure is recommended. With the thermostatic expansion valve at the Sporlan factory setting or at a manufacturer’s predetermined set point, and under the actual minimum load condi-tion, the evaporator pressure regulating valve should