High suction pressure and low head pressure

This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short …

High suction pressure and low head pressure. I will be sharing a pressure chart that may help you troubleshoot low pressure symptoms, high pressure symptoms. As well as other potential problems you may run into when trying to get your r410a or r22 systems to normal operating pressures. ... Outside air temp 95. Running for an hour, suction 120, head pressure between 315-350. Fluctuates ...

Head pressure 190 Suction Pressure 90 Suction line temp 54 inside temp 75 wetbulb 69 So ive been thru this problem b4 with the low head high suction so i assume piston or a-coil . I open up the duct and the other hvac guy has put in a 3ton acoil . I told the neighbor that he should replace the acoil with a 2 1/2 ton .

Low Load. While we often think of the combo of low suction, superheat, and head pressure as being caused by low airflow, it actually falls under a larger heading of low evaporator load. That simply means that the quantity of heat being picked up in the evaporator is lower than the refrigerant mass flow rate requires for the desired operation.An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system.Typical low pressure or suction side pressure for R410A is about 120 psi, varying by ambient temperature, here assuming 75°F, may vary by equipment and metering controls. 3. Typical high side pressure for R410A is < 600 psi at an ambient outdoor temperature of 95 °F, may vary by equipment. 4.Low head pressure may occur simulataneously with high pressure on the suction side of an air conditioner, heat pump or refrigeration system compressor system. If the system …The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches. Increased intra...High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.

Refrigeration service technicians often run service calls in which they find a compressor with a higher-than-normal suction pressure along with a lower-than-normal head pressure. Many times, the refrigeration equipment is still running, but the product temperature is too warm, which causes product quality and safety to suffer.Lower suction pressures generally result in a higher DTD, and higher suction pressures usually result in a lower DTD. When we look at head pressure, we’re actually learning …High Discharge Pressure on heat pump. I was working on a customers heat pump today, A lennox HPXA19-060-230-02 with A cbx32mv-060-230-6-02. It kept short cycling but was giving off 100 f supply. I put my guages on at heat mode and it would trip discharge line temp at 650 PSI (154.7 F) on discharge with a 200 f discharge line temp.Low suction/low head pressures. Bevearage air Prep table not cooling-. R134a, AEA4440YXA hermetic. pressures were about what they should be for a cap tube system (roughly 150/25 psi) but just blowing around warm air. Plate said 7 oz of R134A but I pull out 2 lbs so I evacuate and recharge with 7oz and now the pressures are way down.This low head pressure and higher-than-normal evaporator pressures will decrease the compression ratio of the compressor, causing high volumetric efficiencies. This will increase the pumping rate of the compressor, and a balance may be reached if the compressor can keep up with the high refrigerant flow in the evaporator.higher head pressure and higher subcooling. When any refrigeration system is low on refrigerant it will usually have: low suction and low head pressure. What can cause high superheat in a TEV metered evaporator? ... What combination of symptoms only occurs on a unit with an inefficient compressor? Low head pressure and high suction pressure ...Watch on. Compression ratio is the ratio of head pressure to suction pressure in an HVAC/R unit. Generally, compression ratios approach 2.5:1 on high-efficiency, 16+ SEER A/C systems. The highest compression ratio in A/C compressors is typically 11:1. Refrigeration compression ratios tend to be quite a bit higher (up to 26:1).

Cause #1 Return Duct Leakage:. The suction pressure can be high if the room temp is high, or the return duct has leaks. Cause #2 TXV Improperly feeding: Cause#3 Outdoor/Indoor coil dirty: low airflow situations can cause refrigerant to not completely condense into a liquid, or turn into a gas Cause #4 Unit is Overcharged: One of the most commonly overlooked situations, if you are overcharged ...I just wanted to pick every ones brain i could. I am working on trane condensor and have high head pressure and low suction pressure. It was 90+ out today and I dumped r-22 into the system and no matter what I did I could not get the suction line to sweat and the superheat never dropped below about 20 degrees. my head pressure was around 285 ...problems. Fluid flows from areas of high pressure to areas of low pressure. Pumps operate by creating low pressure at the inlet which allows the liquid to be pushed into the pump by atmospheric or head pressure (pressure due to the liquid’s surface being above the centerline of the pump). Consider placing a pump at the top of the mercurySubaru engines have a radiator and water channel design that uses pumped and pressurized coolant to stabilize its internal temperature. Unlike most internal combustion engines, ins...Terms in this set (54) In order for a system to operate correctly, the high side of the system must have enough _____. Vapor pumped, heat removed from condenser, vapor space. If there is a lack of refrigerant in a system, each pounds of refrigerant will not completely __________. Condense on the high side. When a system is undercharged, the ...Peal. 3 posts · Joined 2009. #46 · Jul 12, 2009 (Edited) I think bwalley is correct. 3 things will cause high head pressure; poor air flow across condenser, overcharge, or non condensable in system. Recover charge, check system for leaks, pull vacuum, and weigh in new charge.

Boogeyman movie theater.

Design or measured suction pressure for a fan is Ps = -380 mm W.G. (-14 in W.G). The correction factor from table above 1.04. For a proper fan selection the suction pressure should be corrected to. Psc = (-380 mm W.G) 1.04. = -395 (mm W.G.) High suction pressure at a fan inlet decreases the density of air - and should be corrected for proper ...Other signs to look for include high head pressure, low suction pressure, and a high temperature difference between the suction and discharge lines. These symptoms may indicate a problem with the system’s balance and should be addressed promptly to avoid further issues. ... Low suction pressure high head pressure is a …OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...I have a suction pressure of 70, converted temp of 41, suction line temp of 51, head pressure of 250, converted temp of 117, head line temp of 96. Air entering condenser is 82 and exit is 100. Air entering evaporator is 76 and exiting is 52.

When a refrigeration system that produces low or no cooling has high suction pressure and high head pressure , it probably A. has an inefficient compressor B. has a low-side restriction C. is overcharged D. is undercharged. Refrigeration and Air Conditioning Technology (MindTap Course List) 8th Edition. ISBN: 9781305578296.To diagnose a bad TXV, look for: Low evaporator pressure. High evaporator and compressor superheats. Low compressor amp draw. Short cycling on the low-pressure control. Higher than normal discharge temperatures. Low condensing pressure. Low condenser split. Normal to high condenser subcooling.units are pressure units, not head units. For simplicity, I’ll stick with NPSH, regardless of the units used. Suction Pressure: The First Half of the NPSH Equation Suction pressure must be determined at the pump suction nozzle when the pump is running. If suction pressure is measured with a gauge, the atmospheric pressure (at the pump location)My suction is running at 45psi and head is at 110psi. I checked evap coil and filter and both were clean, so I figured it was low on R22. I added 7 lbs. (factory charge is 7.25 lbs) and pressures did not change. The suction line is frosting up to the compressor. I'm starting to think I have a bad reversing valve.A patient with low blood pressure, or hypotension, should see a doctor if he experiences dizziness, fainting, irregular heartbeat, breathlessness or chest pain, according to Medlin...So, when pressure in the pump causes more load on the motor, it slows down. When the motor slows down, the flow rate drops at the same percentage. A motor that operates at about 2000 RPM at low pressures will typically slow down to about 1750 RPM when the pump is pressurized to the maximum rating. It stands to reason, then, …This would typically cause a low suction pressure, and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. This can cause extremely high head pressure. In heat mode, a dirty outdoor coil can cause a low suction pressure. As an example, Trane includes a pressure curve chart with many heat pump condensing units.R-22 Low Side Pressure 2: R-22 High Side Pressure 3 °F 1 °C: psig: kpa: Bar-50° ... Typical low pressure or suction side, may vary by equipment and metering controls - these are "gauge pressure readings" or "psig" Typical high …Flashcards Study Guide 29 | Quizlet. In a 2-ton capillary tube system, the unit does not develop full capacity. Heat pressure is low and suction pressure is high. What is the problem? Click the card to flip. BLANK. Quizlet has study tools to help you learn anything. Improve your grades and reach your goals with flashcards, practice tests and ...Reduced system performance. Increased energy consumption. Impact of High Head Pressure. Excessively high head pressure can:The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Low blood pressure, or hypotension, is generally not a concern and requires no treatment in healthy people, according to WebMD. Treatment of hypotension may require treatment of an...

Our diagnostic sheet shows that liquid line restrictions cause low suction pressure and normal to low head pressure, not high head pressure. That’s because the compressor requires refrigerant of a specific density to pump refrigerant into the high side of the system; when the suction pressure is low, the compressor can’t move as much ...

High discharge temperatures can indicate minimal movement of refrigerant. Because the refrigerant isn't being pumped at design rates it stays in the condenser for a longer period of time and is cooled more, hence lower head pressures, and in turn, if the compressor is not pumping well, you will see elevated suction pressures. Reply.This is a low-pressure bypass from the liquid system, as well as high back and low head pressures. What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A.Repeatedly tripping sentronic+. 35 psi net oil press. No press difference between crank and suction. Crankcase heater working. R-22 40 psig suction 160 psig head, 8* sh at comp. sorry no sc data. 40* outdoor ambient. Sh measurements taken at each evap outlet right around 4*. No one evap showing major flooding.1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 …Apple's antitrust defense is moot after a narrow court decision on Monday morning....AAPL Apple (AAPL) shares are feeling even more pressure as the Supreme Court adds to the ba...Mechanical Engineering. When a refrigeration system producing low to normal refrigeration operates continuously without stopping and has high suction pressure and high head pressure , the probable cause is 1. an inefficient compressor 2. a low side restriction 3. noncondensables trapped in the condenser 4. an undercharge of refrigerant.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.temperature efficiency. 9. The approach temperature for the evaporator is. A. the difference between the suction and head pressures converted to temperature. B. the difference between the refrigerant boiling temperature and the suction-line temperature. C. the difference between the refrigerant boiling temperature and the inlet water temperature.Scroll Troubleshooting Solution Chart - Copeland A/C Specific. Deep Vacuum Conditions. Deep vacuum can cause arcing damage to the Fusite pins. Models built after September 1991 have an internal vacuum protection and stop pumping when the pressure exceeds approximate. 10:1. Scroll compressors should never be used to evacuate a system, …

Awesome country boonville ny.

Arizona prison complex florence.

The yen weakened past 150 to the dollar Thursday, adding pressure on officials to intervene in the markets to shore up the currency. Jump to The Japanese yen weakened to above 150 ...The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.When all else seems to function properly, a system with a high suction pressure and a low head pressure suggests _____. the compressor has leaky valves and/or worn piston rings A running burn is indicated by _____.Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F.R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.I just wanted to pick every ones brain i could. I am working on trane condensor and have high head pressure and low suction pressure. It was 90+ out today and I dumped r-22 into the system and no matter what I did I could not get the suction line to sweat and the superheat never dropped below about 20 degrees. my head pressure was around 285 ...Low pulse pressure, or low blood pressure, is not always indicative of a health problem and it is usually not alarming to doctors unless the patient is exhibiting other symptoms ca...We would like to show you a description here but the site won’t allow us.The superheat, SST, and suction pressure will be your key indicators of problems, including defrost issues, clogged TXV strainers, and airflow problems. Overall, rack refrigeration systems work best with high suction pressure and low liquid pressure. Nathan and Bryan also discuss: TD in rack refrigeration; Setting EPR valves; Rack sizing ….

HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Hey guys, need some help i am working on a carrier unit with a Scroll Compressor. I am getting 80 PSIG low side and 165 PSIG high side. Liquid Line is also very hot to the touch. I know this is not normal readings and since it's a scroll compressor, I am thinking about replacing the TXV. High suction pressure plus low head pressure can risk product quality and safety. By John Tomczyk. FIGURE 1: A normal valve plate with suction and discharge valves. ... High Evaporator (Suction) Pressure — Refrigerant vapor will be drawn from the suction line into the compressor’s cylinder during the downstroke of the compressor. …An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...The high head pressure may be due to ____. high ambient temperatures or reduced airflow through the condenser an overcharge of refrigerant, especially if it is a critically charged system Correct! All of the above. a thick coating of dirt and grime on the condenserwe note (and you probably know better than I) that making sense of any refrigerant pressure reading requires also a note of the ambient temperature. If we take 75°F as an example point, R410 low side typical pressure would be about 120 psi and the high side between 410-420 psi. Your high side is a little low.Low suction pressure and high head pressure occur when there’s a drop in refrigerant pressure in the AC system, coupled with elevated output pressure in the compressor. The primary culprit behind this condition is a faulty or malfunctioning TXV valve .Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor pressure — is too low. When fluid pressure on the trailing side of the impeller blade (opposite the pump intake) falls below the vaporization point of the fluid, vapor bubbles begin to form.Step 1. Scale in a geothermal heat pump's fluid system results in an overall increase in fluid temperature high head pressure in the cooling mode and low suction pressure in the heating mode an overall decrease in fluid temperature low head pressure in the cooling mode and high suction pressure in the heating mode. High suction pressure and low head pressure, The suction pressure, on the other hand, is the pressure at the evaporator, where the refrigerant absorbs heat and evaporates. ... Higher loads may result in higher head pressure, while lower loads may lead to lower head pressure. Refrigerant charge: The amount of refrigerant in the system plays a significant role in head pressure control. …, As a minimum, low lube oil pressure, low seal gas pressure differential, overspeed, high discharge gas temperature, high and low suction and discharge …, The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply., A blockage causes high head pressure while suction pressure remains low. This imbalance puts strain on the compressor and reduces cooling efficiency. To troubleshoot, technicians will check for dirty filters, malfunctioning expansion valves, and debris in condenser coils. Clearing these blockages restores proper function to the …, If the system suction pressure on a fixed metering device type unit is too high; the potential causes are; C. Flooded Evaporator Coil, High Evaporator Head Load, Dirty Condenser Coils, Compressor Valve Failures. TXV system problems can exhibit the five following symptoms: a. Normal suction pressure & superheat, with low or high …, Hi, sorry you're having trouble. Low suction and high head is usually due to a restriction in the liquid line. Basically, you're starving the evaporator. If the unit has an expansion valve on the inlet to the evaporator, it may be defective. Some are adjustable, most residential ones, not. I would look there first., When it comes to fashion, comfort is key. Low wedge sandals are the perfect way to look stylish and feel comfortable at the same time. With a variety of styles and colors available..., Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid’s vapor pressure — is too low. When fluid pressure on the trailing side of the impeller blade (opposite the pump intake) falls below the vaporization point of the fluid, vapor bubbles begin to form., Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on …, Cause #1 Return Duct Leakage:. The suction pressure can be high if the room temp is high, or the return duct has leaks. Cause #2 TXV Improperly feeding: Cause#3 Outdoor/Indoor coil dirty: low airflow situations can cause refrigerant to not completely condense into a liquid, or turn into a gas Cause #4 Unit is Overcharged: One of the most commonly overlooked situations, if you are overcharged ..., Table 1: R134a Saturation Properties pressure table (Reference: www.chemours.com) Back to the problem at hand. For any refrigeration cycle/AC unit there are two operating pressures: suction pressure and discharging pressure, high and low settings for each pressure line determined by the manufacturer will stop the unit., The compressor is still cooling, but not to its rated capacity, which can cause refrigerated products to spoil faster and frozen products to begin to thaw. There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. Worn compressor rings; and., Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system., Blog. Pressure Points: Understanding the Importance of Head Pressure in HVAC. December 20, 2023by J & J Services. Table of ContentsToggle. Causes of High Head Pressure. Importance of Proper Head Pressure. Measuring Head and Suction Pressure. Maintaining the Right Head Pressure. Advanced Head Pressure Control Techniques. Conclusion., The compressor is still cooling, but not to its rated capacity, which can cause refrigerated products to spoil faster and frozen products to begin to thaw. There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. Worn compressor rings; and., Hi all (yall) I was doing a PM for a customer and when taking the refrigerant readings, I have come to a complete brain fart as to why the system was doing this. Readings: Indoor temp: 70 F. Outdoor temp: 68 F. Suction Pressure: 65 PSIG (roughly 10 degrees) Discharge Pressure: 205 PSIG (roughly 72 degrees), A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve., External to the compressor are numerous other alarm and shutdown safeguards. As a minimum, low lube oil pressure, low seal gas pressure differential, overspeed, high discharge gas temperature, high and low suction and discharge pressures, and high liquid level in the suction scrubber are monitored and will initiate a …, Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on …, This will cause low suction pressures, high superheats, low amp draws, and low head pressures. Also, the symptoms of a restricted TXV system are very similar to a system with a refrigerant undercharge. However, the undercharged system will have low subcooling levels. Technicians often confuse an undercharged system with a restricted …, Low wedge sandals are a great way to add a touch of style and comfort to any outfit. Whether you’re headed to the office, out for a night on the town, or just running errands, thes..., The high head pressure may be due to ____. high ambient temperatures or reduced airflow through the condenser an overcharge of refrigerant, especially if it is a critically charged system Correct! All of the above. a thick coating of dirt and grime on the condenser, High head pressure is typically accompanied by a low suction pressure. This combination can be indicative of restricted refrigerant. Essentially, this means that air and vaporized water travel through your HVAC’s evaporator until they get to the top of the compressor, where it remains because it will not condense., External to the compressor are numerous other alarm and shutdown safeguards. As a minimum, low lube oil pressure, low seal gas pressure differential, overspeed, high discharge gas temperature, high and low suction and discharge pressures, and high liquid level in the suction scrubber are monitored and will initiate a …, Try our Net positive suction head calculator or: In your reservoir, get fluid surface pressure: P surface. Get the distance between the pump and liquid surface: Z. If the tank is above the pump, multiply this value by -1. Obtain the vapor pressure for the system's temperature: P vapor. Also, its density is ρ. Note that g represents gravity., The net positive suction head (NPSH) of a pump refers to the difference between the suction pressure at the pump's inlet and the fluid's vapor pressure at the system …, problems. Fluid flows from areas of high pressure to areas of low pressure. Pumps operate by creating low pressure at the inlet which allows the liquid to be pushed into the pump by atmospheric or head pressure (pressure due to the liquid’s surface being above the centerline of the pump). Consider placing a pump at the top of the mercury, Net Positive Suction Head (NPSH) NPSH can be defined as two parts: NPSH Available (NPSHA): The absolute pressure at the suction port of the pump. AND. NPSH …, Greetings, I am working on a R22 Lennox Split Heat Pump 3 ½ ton. The unit will trip on the compressor relief valve in heating. I was unable to test the unit S/C and S/H accurately, due to the High Side pressure building up so fast with in a minuet will be hitting 400psi and blow the low side would sit at about 50psi. I tested the RVR from cooling to …, Wakra is a beautiful coastal city in Qatar that is known for its stunning beaches and crystal-clear waters. For beach enthusiasts, one important factor to consider before heading o..., A patient with low blood pressure, or hypotension, should see a doctor if he experiences dizziness, fainting, irregular heartbeat, breathlessness or chest pain, according to Medlin..., The users should set high and low alarms on the EdP output to keep the DP tightly controlled while increasing the flow rate. If the pump doesn’t generate 120 feet total head at the 55 gpm flow rate, this could be your first indication of an operational or mechanical issue. Check the suction pressure and ensure it is greater than NPSHr., Rupturing of the eardrum can occur from a blow to the head, an object pushed into the ear, severe barometric pressure, inner ear infections or from very loud noises. Rupturing of t...