Honeywell hz311 heat red light

View and Download Honeywell TrueZONE HZ311, HZ322, HZ432 manual online. Zoning System Design Manual. TrueZONE HZ311, HZ322, HZ432 controller pdf manual download.

Honeywell hz311 heat red light. The red light on Heat 1 is blinking. Honeywell. HZ322 TrueZone. I turned the white system on - Answered by a verified HVAC Technician ... Recently I replaced a Honeywell EMM-3U Minizone panel with a Honeywell HZ311 Truezone panel with a DATS. For the most part everything works fine except for one issue. When cooling stops the fan contin ...

the red light on the HZ322 indicates a closed zone, while a green light indicates an open zone, only the zone that is calling for heat will be green, if one or both of the zones are not calling for heat the light will be red, it is only a concern if your thermostat is calling for heat and the zone stays red.

1-48 of 58 results for "hz311 honeywell" Results. Price and other details may vary based on product size and color. ... TH8110R1008 Vision Pro 8000 Touch Screen Single Stage Thermostat with Red Link Technology. 4.3 out of 5 stars. 432. ... TB8575A1000 SuitePRO 24 VAC 2 or 4 Pipe 3-Speed Fan Coil Thermostat with Manual/Auto Heat or Cool ...The burner should stay on as long as tstats are calling for heat and until the … read more. I have a red led for circ and the pump is not coming on. The. I have a red led for circ and the pump is not coming on. The boiler did come on briefly. … read more. Utica boiler. UT 1013 control panel red purge light.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r … read moreJustAnswer-Q&A. 8.23K subscribers. Subscribed. 3.9K views 2 years ago. From https://www.justanswer.com/ythi JustAnswer Customer from San Antonio, TX: Hi I …From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: Hello, I have a Honeywell HZ311 zone panel and zone 3 has a solid red light, wh...Nov 28, 2023 · Flashing red heat light. Contractor's Assistant: Im sorry to hear that youre experiencing a flashing red heat light, but our HVAC Technician will be able to help you diagnose and resolve the issue. Can you provide the make and model of your HVAC system? Honeywell hz311 Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Hey Neal, We have a Honeywell HZ311 and only use two zone. Zone 1 & 2 are green while zone 3 and Heat are red. The furnace stats are set to 70, as of the last two weeks throughout the day the furnace …

3 posts · Joined 2017. #1 · Nov 3, 2017. To begin I have a home with a Honeywell HZ311 Controller, single stage heat and cooling. The system has three dampers with zone controlling for the 1st, 2nd and 3rd floor. As a result I have three separate Thermostats (Honeywell Battery Powered). My goal is to install a NEST Thermostat for one location ...I have Honeywell HZ311 and trying to install Nest Learning Thermostat 3rd Gen. The upstairs installation went well. The old thermostat had 5 wires (Yellow, White, Green, Blue, and Red). The downstairs … read moreokay both are now on the panel shows red light on HEAT as well as red light for zone 1 and 3. zone 2 is green nothing is happening ... My honeywell hz311 purge indicated light blinks yellow during the purge cycle an my heat indicator light is solid red. ...1.3K views 2 years ago. From https://www.justanswer.com/ythi JustAnswer Customer from San Antonio, TX: I have a Honeywell HZ311 and the Heat LED is RED. …I have a hz311 Honeywell control panel I have two zones running a hydronic system... the heat works fine but when I turned on the cool mode on thermostat the condenser outside does not run I jumped the condenser outside to check for power it ran. Now inside I have a two wire cable coming from condenser then loops around basement and is tied into another two wire cable witch goes up to where ...Aug 28, 2022 · When zone 2 and 3 red lights show up on the panel, it signifies the thermostat is not cooling or heating. Several reasons can cause the system not to cool. It can be related to the blower motor, damper, or coil starting from a low refrigerant. Hey Neal, We have a Honeywell HZ311 and only use two zone. Zone 1 & 2 are green while zone 3 and Heat are red. The furnace stats are set to 70, as of the last two weeks throughout the day the furnace …

From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: I have a Honeywell hz322.JustAnswer Customer from San Antonio, TX: It has a red...Hi , red light blinking on zone 2 , honeywell HZ311, just replaced battery on thermostat, shutted power off , waiting for 30 minutes. Issue is compressor turns on when is on heat . Contractor's Assistant: Have you checked the air filter to make sure its clean? Yes, its been replacedCopper Tube 38OD Tubing Refrigeration Copper Soft Coil 3/8" OD x 50'. $116.24 / ea. EWC 8X12BMND Zone Damper Ultra-Zone Automatic Opposed Blade 8 x 12 Inch Bottom Mount Power Open/Power Closed. $239.94 / ea. Honeywell Home Zoning Kit Truezone with Dats Transformer and HZ311 Panel 3 Zone 1 Heat/1 Cool 24 Volt.Nov 4, 2019 · Honeywell HZ311 LED. We have a 2 zones, Trane AC and Gas heat single stage (2018), Honeywell HZ311 True Zone and 2 Honeywell 7 day programable thermostats. The system is working OK, i.e. we got heat. What is a mystery to me is the LED of the HZ311 showing RED for heat, dampers when I thought they should be green.

Directions to nrg.

From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: I have a Honeywell HZ311 and the Heat LED is RED.JustAnswer Customer from San A...Save on the Honeywell Home HZ311/U from Build.com. Low Prices + Fast & Free Shipping on Most Orders. ... The TrueZONE® HZ311 Panel is for conventional, single stage applications for up to 3 zones (1H, 1C) at 24 Volts. ... common-sense LEDs, variable-speed fan control, and leaves a smaller environmental footprint. Features: Heat pump or dual ...Honeywell Heater Status Light 8 Flashes. If you see the heater status light flashing red 8 times every 3 seconds, it indicates there is a faulty flammable vapor sensor (FVS). And it happens for 3 known reasons-. Resistance of the FVS going out of range. Wiring to the FVS sensor going bad.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Nov 8, 2017 · Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r … read more

You don't need a case full of Euros to enjoy Berlin. Hold on to your hunger. Watch the lights change from red to green. The sun has begun to set. Graffiti adorned trains pass by. G...Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r … read moreHoneywell HZ311 LED. We have a 2 zones, Trane AC and Gas heat single stage (2018), Honeywell HZ311 True Zone and 2 Honeywell 7 day programable thermostats. The system is working OK, i.e. we got heat. What is a mystery to me is the LED of the HZ311 showing RED for heat, dampers when I thought they should be green.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady red. Zone 2 is heating up with no call for it!Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Honeywell TrueZONE HZ311 Manual (13 pages) Zoning System Design Manual. Brand: Honeywell | Category: Controller | Size: 1.03 MB. Table of Contents. The Concept of Zoning. Need Help. Plan the Zones. Bypass Dampers and Dats.Aug 28, 2022 · When zone 2 and 3 red lights show up on the panel, it signifies the thermostat is not cooling or heating. Several reasons can cause the system not to cool. It can be related to the blower motor, damper, or coil starting from a low refrigerant. Honeywell hx3111 with carrier furnace. Has red light on heat. Calling for heat but getting cool air ... i had an hvac guy out yesterday and he hit the purge override on the Honeywell hz311 and that fixed the issue but now the headlight on the unit is flashing red ...A solid red led light indicate that the zone is closed. Which would probably mean that their is no airflow to that zone. When you pressed the override button it is possible you placed zone 2 in a closed position state, I would try to press the override button, see if that releases the override or cycle power to the unit for 30 sec, send me a picture of the zone controller LED screen and I can ...Flashing red heat light, honeywell hz311, the heater is. I cleaned off the heater elements sensors from any carbon build up ...My HZ311 has the zone 3 light red and the heating isnt working in that part of the house we had a power outage last night if that helps ... My Honeywell hz311 zone 2 and 3 have a red light. Zone 1 (downstairs) works just fine. Upstairs does not blow at all.I have a honeywell HZ221 and the heat LED is solid red, Fan Zone 1&2 are. However the blower will not turn on. I have a - Answered by a verified HVAC Technician ... Hi Pearl. I am reading this thread and have the same issue of a red light on the front on the HZ311 next to the word heat. https: ...

The strange thing is that at the HZ311 zone panel, zone 1 light stays green when the HVAC is in ANY mode (heat, cool, fan OR idle) but the zones 2 & 3 lights switch to Red when the system call for heat, cool OR fan. The damper actuators are currently connected to zone 1 so they are constantly fed 24VAC when in cool, heat, fan OR idle… SO!

honeywell hz311 with wireless thermostats. I am not completley clear on how to wire the hz311 to my radiant heat only. Taco 503-4. What terminals on the hz311 connect to the thermostat zone wires on t … read moreWhen the red light indicator on your Honeywell Hz311 system is illuminated, it's important to take steps to identify and resolve the underlying problem. Here are some troubleshooting steps you can follow: 1. Check for power supply: Ensure that the Hz311 system has a reliable power supply. Check the circuit breaker and make sure it is not ...What I see: This stock responds well to economic recovery....AAPL Lucky break. I touched on this in my Market Recon column this morning. I got lucky. Last week. I mean it makes sen...1.1 Issue 1: No Heat. 1.2 Issue 2: Red Light Flashing. 1.3 Issue 3: System Not Responding. 2 No Heat: Causes And Solutions. 2.1 Identifying The Possible Causes Of No Heat In …Wiring diagram honeywell hz311 Honeywell hz311 hz322 hz432 users manual 70 2321 03 zoning system design Honeywell wiring diagram hz autre mounted panel note. electrical - Honeywell zone panel turning on cool of instead of heat. Honeywell hvac Replacing trolatemp mm-3 with honeywell hz311 Honeywell hz311 wiring diagram. Honeywell image0 hvacMy honeywell hz311 purge indicated light blinks yellow during the purge cycle an my heat indicator light is solid red. ... We don't feel cold air coming out in the rooms, and my Honeywell HZ311 shows zone 2 red light. ...Honeywell TrueZONE HZ311 Manual (13 pages) Zoning System Design Manual. Brand: Honeywell | Category: Controller | Size: 1.03 MB. Table of Contents. The Concept of Zoning. Need Help. Plan the Zones. Bypass Dampers and Dats.The red light flashes 4 times, shut power Off, sanded ground n reattached. Pushed both reset buttons . Power on and it cycles 4 times but won't light. No heat on igniter at any time. Would the igniter be shot or could something else not let it heat up? Answer: Check the hot surface igniter for any signs of cracks often seen as white streaks ...The heat LED on the Honeywell hz311 is red what does that mean. One and a half years old. Since - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... The red heat light is on for my Honeywell HZ311 panel. Heat is putting out cold air.To do this, follow these steps: Remove the batteries from the thermostat. Press and hold down the "+" button for at least 5 seconds. While still holding the "+" button, replace the batteries. Release the "+" button. After performing a hard reset, your thermostat will be cleared of all settings and programs.

Daikers trail cam.

2632 pill v.

Honeywell HZ311 TrueZONE Panel . Visit the Honeywell Store. 4.6 4.6 out of 5 stars 477 ratings | Search this page . 100+ bought in past month. $ ... Heat Pump Compatible: No; Compatible with Sensor: Discharge Air Temperature Sensor. Product Dimension: Height 8 in X Length 8 in X Width 1.86 in. From the manufacturer. Product Features . LEDs: Yes ...Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Hello, on the Hz311 zone controller. green means there is power to that damper circuit and red means no power to that circuit. One of the thermostats on most systems is a 'master' thermostat, and if you set it for example at 50F heating, it will not let any of the other thermostats to go into heating mode if the house is above 50F.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Faulty Zone Board. Short Circuit or Wiring Problem. System Diagnostic Mode. 8 Steps of Honeywell hz311 Troubleshooting Red Light. Step 1: Check the Manual. Step 2: Power Cycling. Step 3: Inspect Zoning Dampers. Step 4: Thermostat Connection. Step 5: Wiring Issues. Step 6: System Settings. Step 7: System Diagnostics. Step 8: Professional Help.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …Honeywell. Red light system problem. I turn off & relight the pilot then 2 - 3 days later there's no hot only Luke warm - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Problems honeywell. My HZ311 has a red light on heat and the. problems honeywell.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …The Honeywell Home TrueZONE® HZ432 Panel for conventional, heat pump, or dual fuel applications expandable up to 32 zones (3H/2C) at 24 Volts.50031314-001 Rev. M28240A. Em Heat LED Em Heat Mode. Much of this information is also listed on the label on the. inside of the HZ221 cover. When the zone panel cover is off, the EMERGENCY HEAT/PURGE OVERRIDE button. is visible. When the panel is in Purge (at startup or after a call for heat/cool), pressing this but-. ….

My honeywell hz311 purge indicated light blinks yellow during the purge cycle an my heat indicator light is solid red. ... I have a honeywell hz311, i have a red light on zones 1 and 2 and a green light on zone 3. We just bought the house so i am unfamiliar with a 3 zone system. Air filter is fine.Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …View and Download Honeywell TrueZONE HZ311 installation manual online. Zone Panel Professional Installation Guide. TrueZONE HZ311 control panel pdf manual download.I have a Honeywell HZ311 unit. I have a red light for heat and red light on zone 2 and zone 3. The unit kicks on but the fans blow cool air and then stop before it reaches the desires temp. Any help much appreciated! Contractor's Assistant: How old is your Honeywell unit? 4 yearsTo begin I have a home with a Honeywell HZ311 Controller, single stage heat and cooling. The system has two dampers with zone controlling for the 1st and 2nd floor. As a result I have two separate Thermostats (Honeywell Battery Powered). My goal is to install a NEST Thermostat for both locations. Per NEST I need to install a C-Wire in order to properly provide power to the device.4 Reasons Behind Honeywell Hz311 Zone 2 & 3 Red Light. Reason 1: Low Refrigerant Level. Solution: Recharging the Refrigerants. Reason 2: Your Blower Motor …Operating: -40° to 165°F (-40° to 74°C) Current Draw: Dimensions: Zone Panel: 6.25 VA max. Page 4 Installation Guide • Guide d’installation • Guía de instalación spECIfICaTIONs aND aCCEssORIEs HZ311 TrueZONE panel dimensions in in. (mm). Encombrement du tableau de régulation par zones TrueZONE HZ311 en po (mm).Dec 31, 2023 · HVAC Technician: RobHVAC. ok that makes sense since you have a zone system. Ok so what this tells me so far is that you either have. 1. loose wire. 2. bad gas valve. 3. bad control board. on the gas valve please make sure the connections are all tight. and also on the control board. Could someone please assist in troubleshooting my AC System. My honeywell hz311 has a zone 3 red light. Zones 1 & 2 are green and cool & fan are green. Outdoor unit is on … Honeywell hz311 heat red light, My system is simple wire wise as it's a 5 zone honeywell 5 wire that are connected in series and two of the thermostat wires fused inside a wall. What I've got is a hz311 zone board a thm 4000r1000 and 2 wireless thermostats. The hz311 doesn't have the abcd connections to link to the thm4000 and I can't find any info on how to link them, My Honeywell HZ311 zone controller is showing a,red light for zone 3 and the AC is not working on the second and third floors. This is a new house in 2016 and everything has been fine until Sunday. Th … read more, Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …, Fan works fine but the heat does not turn on when the heat light turns red on the hz322. If I jumper the fan and heat wires together right at the furnace then the heat turns on. ... I have a Honeywell HZ311 multi zone system. The 3amp fuse blew, so I replaced it with an ATC fuse. The power was restored and the purge light was solid Yellow., The heat LED on the Honeywell hz311 is red what does that mean. One and a half years old. Since - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... The red heat light is on for my Honeywell HZ311 panel. Heat is putting out cold air., Hi, I have a Goodman unit with the hz311 motherboard that shows heat red zone1 green zone 2&3 red ... I have a honeywell hz311, i have a red light on zones 1 and 2 and a green light on zone 3. We just bought the house so i am unfamiliar with a 3 zone system. Air filter is fine., I have Honeywell HZ311 and trying to install Nest Learning Thermostat 3rd Gen. The upstairs installation went well. The old thermostat had 5 wires (Yellow, White, Green, Blue, and Red). The downstairs … read more, Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …, Honeywell TrueZONE Kit with DATS; Transformer and HZ311 Panel. Brand: Honeywell. $41889. Robust Push Terminals. CommonSense LEDs. Clean Professional Installation. Smaller Footprint. VariableSpeed Fan Control., My Honeywell HZ311 has a red light on. One 3 Sorry zone 3 ... I have a dual zone heat pump. The Fan Coil Unit Model FCP3000A that cools/heats the basement and the main floor is located in the basement, and the other Fan Coil Unit Model FCP2400A that cools/heats ..., Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …, I included a pic of my Honeywell HZ311 zone control panel. If I turn the thermostat off all zone lights go green. As soon as I turn on the heat, zone 1 and zone 3 goes red and the purge light comes on … read more, Has red light on heat. Calling for heat but getting cool air. Haven't opened - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... The red heat light is on for my Honeywell HZ311 panel. Heat. Hi. The red heat light is on for my Honeywell HZ311 panel., I have a carrier furnace/AC and a honeywell hz311. I am getting a zone 3 red light and also a moisture sensor ag513e - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Flashing red heat light, honeywell hz311, the heater is., All the red light means is that the board is telling your zone 3 damper to be closed - but it sounds like you only have 2 zones, so that's not an issue, since there's no third zone to …, It has a honeywell hz311 unit on it. heat LED is red, Zone 1 and 2 are green, 3 is red. It is a two zone system. When I cycle the power to the furnace, it comes on, all three zones green with a flashing purge light which is yellow. It'll kick the fan on three times as it attempts to light, I hear the gas come on for a second or two during each ..., Fan works fine but the heat does not turn on when the heat light turns red on the hz322. If I jumper the fan and heat wires together right at the furnace then the heat turns on. ... I have a Honeywell HZ311 multi zone system. The 3amp fuse blew, so I replaced it with an ATC fuse. The power was restored and the purge light was solid Yellow., Honeywell home HZ311 red heat/zone 3 lights. No heat. Heat is not working at all and outside unit is not turning on at all. Lights on my unit in my attic have a red light on heat and zone 3. I tried resetting the circuit breaker in my house for the hvac and resetting the switch the says "furnace on" next to my unit., My honeywell hz311 purge indicated light blinks yellow during the purge cycle an my heat indicator light is solid red. ... I have a honeywell hz311, i have a red light on zones 1 and 2 and a green light on zone 3. We just bought the house so i am unfamiliar with a 3 zone system. Air filter is fine., Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …, Page 3 HZ311 TrueZONE SPECIFICATIONS • CARACTÉRISTIQUES TECHNIQUES • ESPECIFICACIONES Input Ratings: High Limit Setting: Voltage: 18-30 VAC 50/60 Hz transformer of 40 VA When DATS is used, high limit is fixed at 160°F (71°C). or more. High limit should be approximately 15 degrees below furnace high limit., This TrueZONE® HZ322 Panel is for use with conventional and heat pump applications. It can be used with up to 3 zones. Complete with Intuitive Installer setup, the easy-to-follow, digital display uses real language to guide users through four easy steps. Other features include: Standard Checkout Procedure. Robust Push Terminals. Common-Sense LEDs., Wiring Diagrams. 33-00598-01. When used with our RedLINK-enabled TrueZONE® panels, our Wireless Adapter and Wireless FocusPRO® Thermostat you can easily – and wirelessly – add hydronic zoning to a home or add more zones to an existing system. In addition, wireless hydronic zoning introduces the opportunity to increase profit with add-on ..., I have a honeywell hz311, i have a red light on zones 1 and 2 and a green light on zone 3. We just bought the house so i am unfamiliar with a 3 zone system. Air filter is fine. ... The red heat light is on for my Honeywell HZ311 panel. Heat is putting out cold air. ..., Nov 17, 2022 · Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r … , Ok, pressed button for 30 sec and released and seems like it starts burning, but then goes back into lockout mode, red light comes back on. Ok, pressed reset and held for 30 sec, burner sounded like it started …, My heater is not working upon going into the attic I see a red flashing on the hz311 where it says heat. I did. Let me - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Flashing red heat light, honeywell hz311, the heater is., My system is simple wire wise as it's a 5 zone honeywell 5 wire that are connected in series and two of the thermostat wires fused inside a wall. What I've got is a hz311 zone board a thm 4000r1000 and 2 wireless thermostats. The hz311 doesn't have the abcd connections to link to the thm4000 and I can't find any info on how to link them, Returned home and thermostats were all set to heat 65 still, but home was about 50ºF inside. Checked on furnace. Honeywell HZ311 was indicating all three zones FAN ON, and HEAT Led was flashing red. Furnace flue was cool. Searched for answer online. Indicated that DATS may be faulty and to disconnect it to verify., The Honeywell HZ221 control has the Heat on red. Zone 1 and 2 are. the unit is close to 10 years old but the ac unit is - Answered by a verified HVAC Technician ... My Honeywell HZ311 has a Zone3 alarm. ... Hello I have a hz221 panel and the red light for heat is blinking and I have turn off breaker right above the Havac system and also the ..., Got a Honeywell HZ311 Truezone, starting unit (no call on thermostats, OFF), fire up purge steady yellow all 3 Zones green, then pruge light off Zone 1 red, Zone 2 green, Zone 3 red, Head LED steady r …, Upvote. Thermostatic Controls - Honeywell HZ311 TrueZone panel box - I have a Honeywell HZ311 TrueZone panel box. it was installed in Feb. 2012. it operated 3 Honeywell matching thermostats for heat and a/c fine up until now. All 3 thermostats are 5 years old. The HEAT LED on the panel box is solid red. All 3 zones LED are., Nov 4, 2019 · Honeywell HZ311 LED. We have a 2 zones, Trane AC and Gas heat single stage (2018), Honeywell HZ311 True Zone and 2 Honeywell 7 day programable thermostats. The system is working OK, i.e. we got heat. What is a mystery to me is the LED of the HZ311 showing RED for heat, dampers when I thought they should be green.