What size supply duct for 3 ton unit

What size return duct do I need for a 3-ton unit? A 3-ton unit uses approximately 1200 CFMs or approximately 400 CFMs per ton. The lowest you should go is about 350 per ton when the conditions are very humid.

What size supply duct for 3 ton unit. Field convertible airflow (3-12.5 tons). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 15 ton models requires a simple supply duct cover to field convert from factory vertical to horizontal. Easy-adjust, belt-drive motor available.

Very warm winter climates (Average low winter temperatures of 35 degrees and up) 1.5 - 3.0 tons Heat Pump - Use a 5 Kw. 3.5 - 5.0 tons Heat Pump - Use a 10Kw. Mild winter climates (Average low winter temperatures of 25 degrees and up) 1.5 - 2.0 tons Heat Pump - Use a 5 Kw. 2.5 - 5.0 tons Heat Pump - Use a 10Kw.

The Goodman ARUF29B14 air handler is rated for up to 2 tons. In some packages, the air handler will be slightly larger in tonnage than the condenser in the package. This is intentional, as it maintains the overall efficiency of the entire system. From the factory, the unit does need an outdoor unit to function as an AC or heat pump air handler ...When using a duct size calculator CFM is a key factor to consider, as this represents the amount of airflow required for your HVAC system. The duct sizing calculator takes into account a variety of factors, including the airflow rate, static pressure, and velocity. It can help you determine the correct duct size for your HVAC system, taking ...Heat strip would be sized to 80% of 27,230 = 21,790 BTU/HR = 6 kW per ACCA Manual J practice. Two 3 kW heat strips would be practical to handle the Aux Heat down to 10'F with a 2-ton 10 HSPF rated heat pump. Auxiliary heat (one 3 kW strip operating) would typically be necessary at > 22'F and < 34'F.13 Aug 2003 ... How much of the system is returned through this duct? A starting place would be about 100 square inches/ton of cooling (i.e. 12x8 or 10x10).If your are talking about your return duct being 18" x 24" for a 2.5 ton ac then it is sized right. That size of duct will carry at least 2500 cfm of air and your 2.5 ton only needs 1000 cfm. However if you are talking about an 18" x 24" filter grille or just a grille in the wall then that is different and I will let somebody else advise. Reply.

Take this number and multiply by 1,000. Then divide the answer by 12,000. The answer you get is the tonnage or size of your system. Let's say there's a 24 in the model number. Then the tonnage is (24,000/12,000) or 2 tons. If you're putting in a central air conditioning unit you'll be incurring quite an extensive cost.Air handler closet dimensions: Minimum of 30"W x 49.5"H x 32"D for small units and 39"W x 60.5"H x 36"D. Furnace closet dimensions: Minimum 26"W x 40"H x 42"D for small furnaces and 37"W x 46"H x 41"D for large furnaces. Of course, those are minimum dimensions, and the closet can be much larger. But these AC, furnace or ...Aluminum Supply Tubing Clamps, 2.5" (Black), 50pk (UPC-252-50, Unico) ... It can deliver up to 9 tons of air conditioning in the same space as a 3-ton traditional unit. Technical Specifications: Duct Size: 2.5" Matching Duct Type: Aluminum Core: Material: Steel: Duct Connection Type: Clamp: Supply Fitting Type: Clamp:Small Rooftop Units 3 to 15 Tons ... NUMBER USAGE MODEL SIZE TONNAGE SUPPLY AIR BRACKET SUPPLY AIR PICKUP TUBE RETURN AIR BRACKET RETURN AIR PICKUP TUBE CRSMKKIT003A00, CRSMKSEN003A00 48FC, 50FC, 50FCQ 04-07 3 to 6 48TC001809 (tube) ... ed to one or two compatible duct smoke sensors. The clear2 ton does not give you 1000cfm. 2 ton gives you 800 cfm. Also, you need to tell us if you're measuring your return duct by inside measurements or outside measurements. Yes, I understand that 2 ton gives me 800 cfm. The picture just shows that my 12x16 gives me 1000cfm (sufficient for my units' return, maybe).How to size your HVAC ductwork? Understanding measurement units for ducts. Using Modernize's HVAC and ductwork installation calculator. Updated: Feb 16, …12" flex at the recommended residential velocity of 600 Ft/min gives almost exactly 500 cfm. Double that and you're at 1000 cfm which is exactly what a 2.5 ton unit needs (400 sq' per ton). The can size at 14x24 is plenty as well. 600 fpm is not all that fast so that's why it doesn't "feel" strong. It will make for a quiet and very efficient ...

Proper sizing for Supply Trunk. I currently have, in the attic, a 2" duct board supply trunk, with interior dimensions of 12x20", giving an area of 240 in2. It is about 12" long, with no step down in size. This is a 2.5 ton system. According to my calculations, the correct interior size should be 10x18 (180 in2.)The installation costs for a 3-ton air conditioning system generally range between $4,451 and $8,099. However, air conditioner prices vary depending on factors like an HVAC system's type and energy efficiency rating. When you install it, so your actual price could fall outside this average range. You should also remember that a 3-ton cooling ...Adicot, Inc.'s Duct Size Calculator is a versatile and powerful tool designed to assist professionals in the HVAC (Heating, Ventilation, and Air Conditioning) industry. Whether you work with metric or English units, this calculator can handle both, providing convenience and flexibility for users worldwide. Modeled after the renowned original ...We would like to show you a description here but the site won't allow us.780 5th Ave Ste 140, King of Prussia, PA 19406-1437, USA. Contact Information (610) 825-4400 [email protected]

Medieval dynasty reputation.

Average New AC Unit Costs. The average cost of installing a new central air conditioner in 2024, including equipment and labor costs, is $5,750 for a 3-ton unit in a 2,000-square-foot home. On average, a new AC unit cost will …Much like the recommendation to install dampers, I almost always emphasize adding a second return when replacing ductwork.During a major energy upgrade that we recently completed, we had two return ducts- a 14″ in the main house and a 12″ return duct in the master bedroom. That was for a 1.5 ton system and the static was 0.33 inches of water column (IWC).Our townhouse is in Phoenix and is 1400 sq. ft., with two adjoining walls. (The old unit is a 3 ton split system about a zillion years old.) The overall question is whether to go with a 3 or 3.5 ton, which is only about $70 difference in initial cost.Sep 24, 2021 · HVAC systems will have two plenum boxes, one on the supply side and one on the return air side serving as the distribution point for the air. Facebook Twitter Youtube Instagram (833) 526-3787

For a 3-ton unit, we use 18 inch round returns ducts or 20×12, 22×10, and 30×8 rectangular returns ducts. These ducts can facilitate at least 1,200 CFM airflow. For a 3.5-ton unit, we use 20 inch round returns ducts or 22×22, 26×10, and 34×8 rectangular returns ducts.The Digitized Ductulator is a free online calculator for sizing HVAC ducts. Use it in one of two ways; either enter the duct size to find the equivalent CFM, or input the CFM to find the right size of rectangular, round or flex duct. Click here to use the Ductulator. Use the right size duct. Duct that's too big, or too small can cause problems ...A 3.5-ton air-conditioning unit cools homes from 1,801 to 2,300 square feet, depending on location. The unit cools 1,801 to 2,100 square feet in southern states from Georgia to Cal...Gree's High Lift design allows for extended piping length, up to 262 feet total, as well as 50 feet of vertical lift from the condensing units. This allows for greater flexibility in the layout of the system. Allows up to 262 feet of pipe length. Outdoor Unit Indoor Unit Power Supply Transmission System. Energy Saving. A rectangular 6×6-inch duct has an airflow of 110 CFM. Bigger 6×12-inch ducts can handle 270 CFM airflow. The bigger the crosssection of ducts, the bigger CFM; that’s pretty obvious. The smallest 6×4 ducts can handle 60 CFM airflow. The biggest 42×12 ducts with 504 sq inch crosssection can handle 3000+ CFM airflow. Our previous 5 ton unit only had a 16x16 (leading to a 12 inch round) and a 12x12 (leading to a 8 inch round). We had many issues with our previous unit which i believed to be linked to our low return air duct sizes. In the 15 years we owned that unit we had to replace the condensor 3 times (about every 5.I could've spent 14,500 and gotten the same 5 ton unit shoved into the closet that it barely fits in without any testing or mention of ducts, or the need for a larger/multiple return vents. The load calc is just to determine the house needs and has nothing to do with the duct size, right?I'm having a new AC unit and furnace installed, and I have a question about the duct sizes. I had a manual J performed, and they recommended a five ton AC unit. My existing duct is horizontal 12"x27" at the beginning, then it bends upwards and transitions to a 12"x 24". There is ten inch roudn duct shooting off inbetween. This seems small to me for a 5 ton.Trunk/supply duct sizes 3 ton to 2 ton. When I moved it, I had a 3 ton system with only 5 supply ducts (6" flex). The static pressure caused a windstorm in each room. I had two more supply ducts added, and the rest of them increased to a larger size (probably 9" or 10" flex) to lower the static pressure.3. (wrong units) 325 CFM more generally needed for a 3-ton, so 3-ton VERY Likely Underperforming. ------ 1.46 square feet total should be adequate for 2-ton or ~ 50,000 BTU Output furnace/ 800 CFM with ~55'F Rise, BUT # of sharp turns significantly increase resistance and decreases air flow.

This article will guide you in determining the appropriate size for the supply duct of a 5 ton unit. Factors to Consider. Before selecting the size of the supply duct, you need to take into account various factors, including: The BTU (British Thermal Units) rating of the unit; The length of the duct run; Any bends, elbows, or turns in the duct ...

12" flex at the recommended residential velocity of 600 Ft/min gives almost exactly 500 cfm. Double that and you're at 1000 cfm which is exactly what a 2.5 ton unit needs (400 sq' per ton). The can size at 14x24 is plenty as well. 600 fpm is not all that fast so that's why it doesn't "feel" strong. It will make for a quiet and very efficient ...New condensor & coil will be 5 ton. Everything new except duct work. Existing duct work is in concrete floor and is sized 1600 cfm for a 4 ton unit. Current condensor & coil is 4 ton. House has always had problem cooling enough. House is 2,750 sq ft in hot Oklahoma with all brick and large large windows.Originally Posted by tigergrad97. 12" -14"...by appearance anyway. 2-14" would be ok for 3 tons (depending on length and bends/turns. So your a bit small for 3 tons if 1 is 12" and the other 14". Which may be why your current 3 ton struggles on some days. Reply. 11-10-2010, 09:09 PM #10. tedkidd. Professional Member*.July 29, 2022 | By Rene Langer. Return air duct size for 1-5 ton ACs is 14" to 22" for round ducts and 13"x12" to 32"x12" for rectangular ducts. Use the return air duct size calculator below for accurate dimensions required for your air conditioner or heat pump.A TXV is used for precise metering on the 6 ton to 12.5 ton and high SEER 3 ton to 5 ton products and a fixed orifice is used to keep the cost of the product down on the 3 ton to 5 ton product. Two independent refrigerant circuits and compressors are used on the 7.5 ton to 12.5 ton units for economical and precise control. This air handler unit features a built-in humidifier, ERV, and auxiliary heat control inputs. The SVZ is an ideal replacement for traditional forced-air systems or adding to new additions. Capacities: 12,000 to 36,000 BTU/H. Sound: as low as 29 dB (A) SEER: up to 18.0. HSPF: up to 13.6. Step 3. Calculate the return duct size based on the air conditioner's size and the type of duct you are using. Use the following formulas: For rectangular duct: Size of air conditioner (example: 4 tons) x 144 square inches = return air duct in square inches. For round duct: Diameter of duct x 3.14 = return air duct in square inches.Table 4.1 Supply Air Duct Installation Sizes (Based on .08 inches of pressure drop per 100 ft.) Round Duct Rectangular Duct CFM Dia. WxH WxH WxH WxH WxH WxH WxH WxH 80 8x4 90 8x4 100 6 6x6 7x5 9x4 125 7x6 8x5 10x4 150 8x6 9x5 11x4 175 7 7x7 9x6 11x5 13x4 200 8x8 8x7 9x6 12x5 15x4What size supply duct for 2.5 ton ac unit? Updated: 9/20/2023. Wiki User. ∙ 12y ago. Add an answer. Want this question answered? Be notified when an answer is posted.

Jeff mountain monsters age.

Papa johns coupons august 2023.

May 25, 2013 · A common 5 ton system would be 2000 CFM (400 CFM per ton) so a 24x30 register or grill (-.02" sp) with (10) feet of 24x12 duct (-.092"/100') with a duct transition to the RA opening of the unit (if duct is needed) would be a fairly low loss system. Reply. 05-29-2013, 06:08 PM #3. HVAC_HUSKER. Everything I've read on HVAC forums says I need 1200 CFM for a 3 ton unit and that equates to 18" flex duct. My contractor is insisting that 16" flex is adequate and that I should trust his 50 years of experience. Should I insist on the 18" flex return? I am going to be replacing the grille myself at a later date. Add a Comment. Sort by:Nominal Tonage Module Size Supply Duct S Return Duct R 2.5-5 48 x 24 46 3/4 x 22 3/4 36 1/8 x 12 1/8 ... Specified roof top A.C. units will utilize a concentric supply/return ... complete with fixed blade extruded concentric diffuser and plenum. The diffusers shall be compatible with 2½ - 25 ton unitary package equipment as shown in the plans ...Rectangular sheet metal duct = .07" on most metal duct calculators. 2900. 40x12. 100 31/2 x14 2200 38x10 220 31/2 x30 2350 40x10. Rectangular sheet metal duct = .07" on most metal duct calculators. 3050. 42x12.Hello! I am the owner for 9 months of a 3,500 sqft one-story home over full basement in central NJ. It was built 25 years ago and is of average++ construction. The heating and A/C is provided by 2 identical natural-gas, forced air furnaces and 2 X 3-ton A/C. All ducts are in the basement. The furnaces and A/C are original, so about 25 years old, Carrier units, 100K BTUH furnaces that have a ...Basis. 1 No - - No No There is no fan to shutdown; system does not an "air distribution system". - NFPA 90A 6.4.2.1 2 Yes Yes Any No No Not required for fan units whose sole function is to remove air from inside building. - NFPA 90A 6.4.2.3 3 Yes No < 2,000 CFM No No Fan is too small to require shutdown.Oct 1, 2023 · What size ductwork for a 3.5-ton unit? For a 3.5-ton HVAC unit, you would typically use ductwork that can accommodate the required CFM while maintaining proper air velocity. Refer to HVAC duct sizing guidelines for sizing details. How many CFM do I need for a 3-ton unit? A 3-ton HVAC unit typically requires around 1,200 to 1,400 CFM of airflow ... Rectangular sheet metal duct = .07" on most metal duct calculators. 2900. 40x12. 100 31/2 x14 2200 38x10 220 31/2 x30 2350 40x10. Rectangular sheet metal duct = .07" on most metal duct calculators. 3050. 42x12.The downstairs unit cools great - no problems there. The upstairs unit is an upflow unit in the attic, RUUD UGPJ-07EAUER and the outdoor piece is a RUUD UADD-036J 3 ton 10 SEER The upstairs is about 1250 SQft. I've seen their Manual-J and also had an independent calculation done and 3 tons is indeed the right size based on this calc.The maximum rises in temperature for PVC and steel pipes are 10.3 and 12.7 °C respectively. HVAC Duct Size Rules of Thumb - Cooling. Cooling mode: Air flow required: 400 CFM of air flow per Ton of A/C (1 Ton equals 12,000 BTU) ... So a 1 ton A/C unit moves say 400 CFM. ... The actual supply register location, size, design, and the boot ... ….

It's a two ton unit and I can't figure out how to size the plenum. The Air handler is central in the attic, only 6 runs so I'm going to do a radial duct system. Example. System Info-. 2 ton system with supply air opening of 16.375 x 11.3 Inches. 6 flex duct runs total; 5 8" runs 1 4" run. Longest run is 15 feet. 1.A BTU is what's required to heat or cool one pound of water by 1 degree Fahrenheit. For example, your home's square footage total, including all floors and ceilings, is what determines what size what size HVAC unit you need. For every 500 BTUs required for your home, you will need approximately one ton of air conditioning or heating capacity (1 ...HVAC system prices can have a $2,800.00 difference in cost depending on the tonnage you need. A 2-ton HVAC replacement cost around $7,134.17, while a 5-ton HVAC unit cost will run closer to $9,906.57. The below grid will help give you a better idea of the cost to replace an HVAC system based on the size and type you need.The duct is 250mm and approx total is 1 meter duct run on each side of the coil. This unit works equally well in heating or cooling but I have had to boost the static pressure of the fan to say 30PA. The 2nd unit though serves two rooms (spare bedroom & bathroom), I use the same style and size return and supply grills.S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER's up to 11.1. S IEER's up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andAluminum Supply Tubing Clamps, 2.5" (Black), 50pk (UPC-252-50, Unico) ... It can deliver up to 9 tons of air conditioning in the same space as a 3-ton traditional unit. Technical Specifications: Duct Size: 2.5" Matching Duct Type: Aluminum Core: Material: Steel: Duct Connection Type: Clamp: Supply Fitting Type: Clamp:Our guide contains CFM charts for duct sizing, CFM per ton, unit sizing, round to square duct conversions, and more! top of page. PINPOINT AIR. YOUR LOCAL HVAC SOLUTION. Home. Services. Repair Services; ... Sizing for a 2.5 Ton unit, we start with a 16" supply at 875 CFM -1125 CFM. We then take a 7" and 5" run (-200 CFM) off …Here is how it works. Once the air (energy) leaves the furnace blower it begins to travel down the main supply duct. This duct has a certain cross-sectional area. An example would be a duct 8" high by 22" wide. Before the blower turns on, this duct, as well as all of the other ducts, are full of air. What size supply duct for 3 ton unit, We are having 3ton heat pump installed to replace a 2 1/2 ton A/C. Contractor is in presently installing new return duct. Original duct started at a 20x24 ceiling grille and ran through several elbows to air handler suction. It was mostly 20x24. New duct starts after first original 20x24 elbow but then reduces immediately to 10x18. This runs about 16ft and then through an elbow into air ..., December 8, 2022. By MR COOL. The Air Conditioning Contractors of America (ACCA) has developed standards and protocols for designing and installing HVAC equipment and duct work. Properly designed HVAC systems must go through the process of each of the four protocols — J, S, T and D. A correct Manual Calculation leads to a well-designed HVAC ..., Frequently Asked Questions. What return duct size do I need for a 2 Ton unit? For a 2 ton unit you can use either a 19″ flex duct or one of the following rectangular ducts: 14″x13″, 15″x12″, 17″x11″, 18″x10″, 21″x9″, 24″x8″, 28″x7″, 36″x6″. What is the Duct Size For a 4 Ton Unit?, The output from the calculator will give you up to 4 duct size options to choose from: 1 round size and up to 3 rectangular size options. The round duct size gives the size in diameter; The rectangular duct options give the width and height. You can choose 1 of the 4 sizes for your home based on what work best for its layout., Proper sizing for Supply Trunk. I currently have, in the attic, a 2" duct board supply trunk, with interior dimensions of 12x20", giving an area of 240 in2. It is about 12" long, with no step down in size. This is a 2.5 ton system. According to my calculations, the correct interior size should be 10x18 (180 in2.), 14. Shorten the ducts by not putting supplies at the perimeter. This one goes with step 9. You don't need to put the ducts at the perimeter in new homes because we have much better windows. You can shorten the overall duct length and total effective length by not running the supply ducts out to the perimeter., I have received quotes from different companies to replace my 20 year old 4 ton central a/c system. The existing system has 3/4 inch copper tubing for the refrigerant. I am looking at replacing the unit to a 4 ton Infinity or Performance series Carrier or a XR or XLi series Trane system., A round 18-inch is 255 sqin. Almost comparable to my own house, when I bought it -- my AC system was 3.5 ton with 255 sqin return. With a 4.0 ton air handler blowing 1600 cfm, I calculate 823 feet/min air velocity for you. Hard duct can work with higher velocities than flex for supply (but not for return), Manual D still recommends 600 feet/min ..., I currently just have one return that comes in to my garage and it is 12 x 18. He said that 5 tons need to breathe alot and that he wants to get it as close to 20 x 20 as possible. Another thing that my current unit has is a "U" pipe that connects to the bottom of my evaporator unit and the return pipe. He said he will., The high cost is $15,000 for a packaged HVAC unit installation with a SEER rating of 21, with moderate modifications to the ducts. 5-Ton AC Unit Cost Calculator. If you have a home over 3,500 sq.ft in size, you need a 5-ton AC unit to cool it properly. 5-ton units produce roughly 60,000 BTUs., QUICK-GUIDE. Select the duct material from the drop-down list (most duct sizing tools are typically based on galvanised steel ducting by default) Enter the air flowrate in cubic feet per minute (CFM) Enter an internal duct size in inches (this must be limited to a maximum aspect ratio of 5:1 for the results to be valid) The resulting velocity ..., A 3-ton air conditioning unit can hold 6 to 12 pounds of Freon, depending on the unit. The exact amount of Freon needed is determined by a variety of factors, such as the type of u..., Jun 10, 2011 · 4-ton = 1,400 CFM. @ 300 Feet per Min for Filter Area. Minimum Filter Area should be 4.7 Square Feet ( 670 Square Inch) 20"x25" = 500 Square Inch or about 3.5 Square Feet. Need 170 (670 - 500) square inch (1.2 Sq. Feet) more of filter area. Designer Dan __ It's Not Rocket Science, But It is SCIENCE with Some Art. , highlights. The Goodman® GPH14M 14 SEER Packaged Heat Pump provides energy-efficient cooling and heating performance in one self-contained unit. The Goodman GPH14M is housed in a heavy-gauge, galvanized-steel cabinet that offers a high-quality, UV-resistant powder-paint finish and allows for a ground-level or rooftop mount., One contractor say to go with a 3.5 ton. One says 2.5 because of my small duct size. The ductwork measures 8 by 14 at the furnace but 6 by 10 inches at the wall vents. ... Your 34x8 supply duct seems to be the limiter at 3 1/2 tons. However, there could be other factors which may reduce that number. The contractor suggesting 2 1/2 tons very ..., It's a two ton unit and I can't figure out how to size the plenum. The Air handler is central in the attic, only 6 runs so I'm going to do a radial duct system. Example. System Info-. 2 ton system with supply air opening of 16.375 x 11.3 Inches. 6 flex duct runs total; 5 8" runs 1 4" run. Longest run is 15 feet. 1., Buy Goodman GPGM33608041 3 Ton Cooling / 80,000 BTU Heating, 13.4 SEER2 Packaged Unit. ... duct work. The packaged unit can also be easily converted to accommodate a plenum for normal or low-static applications. The Goodman packaged unit series are self-contained so the only connections needed for installation are the supply and return ducts ..., sees VRV regularly utilized in all project sizes from 3 ton to several 1,000 ton. Simple Modular Design SPECIFICATIONS & ACCESSORIES SYSTEM OVERVIEW SYSTEM SELECTION ... Indoor Unit Size 07 09 12 15 18 24 30 36 42 48 54 72 96 Indoor Unit Capacity Index 7.5 9.5 12 15 18 24 30 36 42 48 54 72 96. 12, Then you could easily figure what size filter you need for that CFM of airflow to get say 300 ft./m of airflow velocity through a new filter, being that it is the fiberglass filter. We will say in the cooling mode you want to flow 1250 CFM of air volume for a 3 ton AC or heat pump through the system; 1250÷300 is 4.1666 ft.² of free air area ..., highlights. The Goodman® GPH14M 14 SEER Packaged Heat Pump provides energy-efficient cooling and heating performance in one self-contained unit. The Goodman GPH14M is housed in a heavy-gauge, galvanized-steel cabinet that offers a high-quality, UV-resistant powder-paint finish and allows for a ground-level or rooftop mount., Our ducted AC units are an ideal choice for hotels, restaurants, hospitals, resorts, villas, offices etc. What is Ductable air conditioning? A ducted air-conditioning installation is a type of central air conditioning that consists of an air distribution system that is carried out through a series of tubes installed in the false ceiling of the home or premises., Comfortmaker Ion™ CSH6 - The best single-stage 3-ton heat pump. With a cooling capacity that varies from 1.5 to 5 tons, the Comfortmaker Ion™ CSH6 heat pump is suitable for both small and large spaces. The unit features a single-stage scroll compressor and a single-speed fan motor that ensure stable output. Moreover, the CSH6 can switch ..., Post Likes. The (minimum) rule of thumb is 5 outlets per ton. A long supply run will have an effect on the airflow it can deliver. The last Unico (or it may have been a SpacePac) I bid needed to have the "plenum" enlarged from the original 7" to 9" and then I need to re-route some of the supplies off of the 9"., Our fan coil units come in three basic configurations: horizontal in or along the ceiling, vertical running the height of the wall, and unit heaters low along the wall. ThinLine Fan Coils and Unit Heaters. 200 to 1,200 CFM. Product Info. OptiLine™ Vertical Stacked Fan Coils. 300 to 1,200 CFM. Product Info., Originally Posted by tigergrad97. 12" -14"...by appearance anyway. 2-14" would be ok for 3 tons (depending on length and bends/turns. So your a bit small for 3 tons if 1 is 12" and the other 14". Which may be why your current 3 ton struggles on some days. Reply. 11-10-2010, 09:09 PM #10. tedkidd. Professional Member*., It made a huge difference, dropping the pressure in the bedroom (relative to the hallway) from about 6.7 Pascals (Pa) to about 1.7 Pa. The ENERGY STAR new homes program requires pressure balancing of bedrooms with a maximum pressure difference of 3.0 Pa., The length, width, and number of the various duct branches and components that are fed from the main trunk can all affect this metric. Cubic Feet per Minute: For a simple calculation, multiply the size of the HVAC unit (expressed in tons) by 400. Next, divide that number by your home's square footage. Although this is the basic formula ..., We would like to show you a description here but the site won't allow us., How large should return air duct be? A typical supply vent is 4 by 10 to 12 inches and a typical return vent is 16 by 20 inches or larger. ... your return air duct and grill size will be 24 by 24 inches.) Always place return ducts as far away from the supply air vents as possible. ... You have a 3 ton unit which is 1200 cfm’s. As r mentioned ..., The right size of return duct for a 3.5 ton AC is 22 X 22 inches. In the case of a 4 ton AC, it’s 24 X 24 inches. And for a 5 ton AC, the correct size is 27 X 27 inches. Calculate the return duct size. And multiply AC tonnage by 3.14 for round and 144 square inches. This is for rectangular ducts. Now, we have all the answers and calculations ..., Air Flow 6,000 cfm @ 5" ESP Voltage 460 V / 3 phase / 60 hertz Supply Air Duct (3) 20" Disconnect Size Return Air Duct NA - Louvered Inlet Connection Filter Size (3) 24"x24"x2" Cables Circuits / Compressors 1 / 1 FLA / MCA Cooling 100 / 125 amps ... Unit Arrangement - Dimensions are Approximate 0040 TAC 40 Ó2021 Carrier. All Rights ..., For a three-ton unit, you will require an 18″ round air duct size for your ductwork. If you intend to use a rectangular air duct, you need a ductwork size of …, By using this equation, we can determine the size of the return grille we need for 400 CFM airflow like this: Grille Area (400 CFM) = 400 CFM ÷ 500 FPM ÷ 0.7 × 144 = 164 Sq In. That means we will need a grill with at least 164 square inches of area to accommodate for a 400 CFM airflow. 10×10 grille, for example, has a 100 sq in area; it ...